Shopping Cart
No items in shopping cart
Continue shoppingNo items in shopping cart
Continue shopping
In partner stock - ships in 3-5 days
SINAMICS G120C RATED POWER 0,75KW WITH 150% OVERLOAD FOR 3 SEC 3AC380-480V +10/-20% 47-63HZ INTEGRATED FILTER CLASS A I/O-INTERFACE: 6DI, 2DO,1AI,1AO SAFE TORQUE OFF INTEGRATED FIELDBUS: PROFIBUS-DP PROTECTION: IP20/ UL OPEN TYPE SIZE: FSA 196X73X203(HXWXD) EXTERNAL 24V

SINAMICS G120C RATED POWER 0,75KW WITH 150% OVERLOAD FOR 3 SEC 3AC380-480V +10/-20% 47-63HZ INTEGRATED FILTER CLASS A I/O-INTERFACE: 6DI, 2DO,1AI,1AO SAFE TORQUE OFF INTEGRATED FIELDBUS: PROFIBUS-DP PROTECTION: IP20/ UL OPEN TYPE SIZE: FSA 196X73X203(HXWXD) EXTERNAL 24V
In partner stock - ships in 3-5 days
In partner stock - ships in 3-5 days
SINAMICS G120C RATED POWER 1,1KW WITH 150% OVERLOAD FOR 3 SEC 3AC380-480V +10/-20% 47-63HZ UNFILTERED I/O-INTERFACE: 6DI, 2DO,1AI,1AO SAFE TORQUE OFF INTEGRATED FIELDBUS: USS/ MODBUS RTU PROTECTION: IP20/ UL OPEN TYPE SIZE: FSAA 173X73X155(HXWXD) EXTERNAL
SINAMICS G120C RATED POWER 1,1KW WITH 150% OVERLOAD FOR 3 SEC 3AC380-480V +10/-20% 47-63HZ UNFILTERED I/O-INTERFACE: 6DI, 2DO,1AI,1AO SAFE TORQUE OFF INTEGRATED FIELDBUS: USS/ MODBUS RTU PROTECTION: IP20/ UL OPEN TYPE SIZE: FSAA 173X73X155(HXWXD) EXTERNAL
In partner stock - ships in 3-5 days

In partner stock - ships in 3-5 days
SINAMICS G120C RATED POWER 1,5KW WITH 150% OVERLOAD FOR 3 SEC 3AC380-480V +10/-20% 47-63HZ INTEGRATED FILTER CLASS A I/O-INTERFACE: 6DI, 2DO,1AI,1AO SAFE TORQUE OFF INTEGRATED FIELDBUS: PROFINET-PN PROTECTION: IP20/ UL OPEN TYPE SIZE: FSA 196X73X225,4(HXW

SINAMICS G120C RATED POWER 1,5KW WITH 150% OVERLOAD FOR 3 SEC 3AC380-480V +10/-20% 47-63HZ INTEGRATED FILTER CLASS A I/O-INTERFACE: 6DI, 2DO,1AI,1AO SAFE TORQUE OFF INTEGRATED FIELDBUS: PROFINET-PN PROTECTION: IP20/ UL OPEN TYPE SIZE: FSA 196X73X225,4(HXW
In partner stock - ships in 3-5 days
In partner stock - ships in 3-5 days
SINAMICS G120C RATED POWER 2,2KW WITH 150% OVERLOAD FOR 3 SEC 3AC380-480V +10/-20% 47-63HZ UNFILTERED I/O-INTERFACE: 6DI, 2DO,1AI,1AO SAFE TORQUE OFF INTEGRATED FIELDBUS: USS/ MODBUS RTU PROTECTION: IP20/ UL OPEN TYPE SIZE: FSAA 173X73X155(HXWXD) EXTERNAL
SINAMICS G120C RATED POWER 2,2KW WITH 150% OVERLOAD FOR 3 SEC 3AC380-480V +10/-20% 47-63HZ UNFILTERED I/O-INTERFACE: 6DI, 2DO,1AI,1AO SAFE TORQUE OFF INTEGRATED FIELDBUS: USS/ MODBUS RTU PROTECTION: IP20/ UL OPEN TYPE SIZE: FSAA 173X73X155(HXWXD) EXTERNAL
In partner stock - ships in 3-5 days

In partner stock - ships in 3-5 days
SINAMICS G120C RATED POWER 5,5KW WITH 150% OVERLOAD FOR 3 SEC 3AC380-480V +10/-20% 47-63HZ INTEGRATED FILTER CLASS A I/O-INTERFACE: 6DI, 2DO,1AI,1AO SAFE TORQUE OFF INTEGRATED FIELDBUS: PROFIBUS-DP PROTECTION: IP20/ UL OPEN TYPE SIZE: FSB 196X100X203(HXWXD) EXTERNAL 24V

SINAMICS G120C RATED POWER 5,5KW WITH 150% OVERLOAD FOR 3 SEC 3AC380-480V +10/-20% 47-63HZ INTEGRATED FILTER CLASS A I/O-INTERFACE: 6DI, 2DO,1AI,1AO SAFE TORQUE OFF INTEGRATED FIELDBUS: PROFIBUS-DP PROTECTION: IP20/ UL OPEN TYPE SIZE: FSB 196X100X203(HXWXD) EXTERNAL 24V
In partner stock - ships in 3-5 days

In partner stock - ships in 3-5 days
SINAMICS G120C RATED POWER 7,5KW WITH 150% OVERLOAD FOR 3 SEC 3AC380-480V +10/-20% 47-63HZ INTEGRATED FILTER CLASS A I/O-INTERFACE: 6DI, 2DO,1AI,1AO SAFE TORQUE OFF INTEGRATED FIELDBUS: PROFIBUS-DP PROTECTION: IP20/ UL OPEN TYPE SIZE: FSB 196X100X203(HXWX

SINAMICS G120C RATED POWER 7,5KW WITH 150% OVERLOAD FOR 3 SEC 3AC380-480V +10/-20% 47-63HZ INTEGRATED FILTER CLASS A I/O-INTERFACE: 6DI, 2DO,1AI,1AO SAFE TORQUE OFF INTEGRATED FIELDBUS: PROFIBUS-DP PROTECTION: IP20/ UL OPEN TYPE SIZE: FSB 196X100X203(HXWX
In partner stock - ships in 3-5 days

In partner stock - ships in 3-5 days
SINAMICS G120C RATED POWER 11,0KW WITH 150% OVERLOAD FOR 3 SEC 3AC380-480V +10/-20% 47-63HZ INTEGRATED FILTER CLASS A I/O-INTERFACE: 6DI, 2DO,1AI,1AO SAFE TORQUE OFF INTEGRATED FIELDBUS: USS/ MODBUS RTU; PROTECTION: IP20/ UL OPEN TYPE SIZE: FSC 295X140X203(HXWXD) EXTERNAL 24V

SINAMICS G120C RATED POWER 11,0KW WITH 150% OVERLOAD FOR 3 SEC 3AC380-480V +10/-20% 47-63HZ INTEGRATED FILTER CLASS A I/O-INTERFACE: 6DI, 2DO,1AI,1AO SAFE TORQUE OFF INTEGRATED FIELDBUS: USS/ MODBUS RTU; PROTECTION: IP20/ UL OPEN TYPE SIZE: FSC 295X140X203(HXWXD) EXTERNAL 24V
In partner stock - ships in 3-5 days

In partner stock - ships in 3-5 days
SINAMICS G120 POWER MODULE PM230 WITH BUILT IN CL. A FILTER PROTECTION IP20 3AC380-480V +10/-10% 47-63HZ OUTPUT LOW OVERLOAD: 7,5KW FOR 150% 3S,110% 57S,100% 240S AMBIENT TEMP 0 TO +40 DEG C(LO) 292 X 100 X 165 (HXWXD), FSB WITHOUT CONTROL UNIT AND PANEL APPROVED FOR CU240B/E-2 AND CU230P-2 FIRMWARE-VERSION V4.4 NOTE: PM230 DOES NOT SUPPORT SAFETY

SINAMICS G120 POWER MODULE PM230 WITH BUILT IN CL. A FILTER PROTECTION IP20 3AC380-480V +10/-10% 47-63HZ OUTPUT LOW OVERLOAD: 7,5KW FOR 150% 3S,110% 57S,100% 240S AMBIENT TEMP 0 TO +40 DEG C(LO) 292 X 100 X 165 (HXWXD), FSB WITHOUT CONTROL UNIT AND PANEL APPROVED FOR CU240B/E-2 AND CU230P-2 FIRMWARE-VERSION V4.4 NOTE: PM230 DOES NOT SUPPORT SAFETY
In partner stock - ships in 3-5 days

In partner stock - ships in 3-5 days
SINAMICS G120 POWER MODULE PM230 UNFILTERED DEGREE OF PROTECTION IP20 380-480 V 3 AC +10/-10% 47-63 HZ POWER LOW OVERLOAD: 11KW AT 150% 3S, 110% 57S, 100% 240 S; AMBIENT TEMPERATURE 0 TO +40 °C (LO) 355X 140X 165 (HXWXD), FSC WITHOUT CONTROL UNIT AND OPERATING UNIT RELEASED FOR CU240B/E-2 AND CU230P-2 FIRMWARE VERSION V4.4 OR HIGHER NOTE: PM230 SUPPORTED NO SAFETY

SINAMICS G120 POWER MODULE PM230 UNFILTERED DEGREE OF PROTECTION IP20 380-480 V 3 AC +10/-10% 47-63 HZ POWER LOW OVERLOAD: 11KW AT 150% 3S, 110% 57S, 100% 240 S; AMBIENT TEMPERATURE 0 TO +40 °C (LO) 355X 140X 165 (HXWXD), FSC WITHOUT CONTROL UNIT AND OPERATING UNIT RELEASED FOR CU240B/E-2 AND CU230P-2 FIRMWARE VERSION V4.4 OR HIGHER NOTE: PM230 SUPPORTED NO SAFETY
In partner stock - ships in 3-5 days
In partner stock - ships in 3-5 days
SINAMICS G120 POWER MODULE PM230 WITH BUILT IN CL. A FILTER PROTECTION IP20 3AC380-480V +10/-10% 47-63HZ OUTPUT LOW OVERLOAD: 15KW FOR 150% 3S,110% 57S,100% 240S AMBIENT TEMP 0 TO +40 DEG C(LO) 355 X 140 X 165 (HXWXD), FSC WITHOUT CONTROL UNIT AND PANEL APPROVED FOR CU240B/E-2 AND CU230P-2 FIRMWARE-VERSION V4.4 NOTE: PM230 DOES NOT SUPPORT SAFETY
SINAMICS G120 POWER MODULE PM230 WITH BUILT IN CL. A FILTER PROTECTION IP20 3AC380-480V +10/-10% 47-63HZ OUTPUT LOW OVERLOAD: 15KW FOR 150% 3S,110% 57S,100% 240S AMBIENT TEMP 0 TO +40 DEG C(LO) 355 X 140 X 165 (HXWXD), FSC WITHOUT CONTROL UNIT AND PANEL APPROVED FOR CU240B/E-2 AND CU230P-2 FIRMWARE-VERSION V4.4 NOTE: PM230 DOES NOT SUPPORT SAFETY
In partner stock - ships in 3-5 days

In partner stock - ships in 3-5 days
SINAMICS POWER MODULE PM240-2 WITH INTEGRATED CLASS A FILTER WITH INTEGRATED BRAKING CHOPPER 380-480 V 3 AC +10/-10% 47-63 HZ POWER HIGH OVERLOAD: 0.37KW AT 200% 3S, 150% 57S, 100% 240 S; AMBIENT TEMPERATURE -10 TO +50 °C; POWER LOW OVERLOAD: 0.55KW AT 15

SINAMICS POWER MODULE PM240-2 WITH INTEGRATED CLASS A FILTER WITH INTEGRATED BRAKING CHOPPER 380-480 V 3 AC +10/-10% 47-63 HZ POWER HIGH OVERLOAD: 0.37KW AT 200% 3S, 150% 57S, 100% 240 S; AMBIENT TEMPERATURE -10 TO +50 °C; POWER LOW OVERLOAD: 0.55KW AT 15
In partner stock - ships in 3-5 days

In partner stock - ships in 3-5 days
SINAMICS POWER MODULE PM240-2 UNFILTERED WITH INTEGRATED BRAKING CHOPPER 380-480 V 3 AC +10/-10% 47-63 HZ POWER HIGH OVERLOAD: 0.55KW AT 200% 3S, 150% 57S, 100% 240 S; AMBIENT TEMPERATURE -10 TO +50 °C; POWER LOW OVERLOAD: 0.75KW AT 150% 3S, 110% 57S, 100

SINAMICS POWER MODULE PM240-2 UNFILTERED WITH INTEGRATED BRAKING CHOPPER 380-480 V 3 AC +10/-10% 47-63 HZ POWER HIGH OVERLOAD: 0.55KW AT 200% 3S, 150% 57S, 100% 240 S; AMBIENT TEMPERATURE -10 TO +50 °C; POWER LOW OVERLOAD: 0.75KW AT 150% 3S, 110% 57S, 100
In partner stock - ships in 3-5 days

In partner stock - ships in 3-5 days
SINAMICS G120 POWER MODULE PM240-2 UNFILTERED WITH BUILT IN BRAKING CHOPPER 3AC380-480V +10/-10% 47-63HZ OUTPUT HIGH OVERLOAD: 1,1KW FOR 200% 3S,150% 57S,100% 240S AMBIENT TEMP. -10 TO +50 DEG C OUTPUT LOW OVERLOAD: 1,5KW AT 150% 3S,110% 57S,100% 240S AMBIENT TEMP. -10 TO +40 DEG C 196 X 73 X 165 (HXWXD), FSA PROTECTION IP20 WITHOUT CONTROL UNIT AND PANEL APPROVED FOR FIRMWARE-VERSION V4.6

SINAMICS G120 POWER MODULE PM240-2 UNFILTERED WITH BUILT IN BRAKING CHOPPER 3AC380-480V +10/-10% 47-63HZ OUTPUT HIGH OVERLOAD: 1,1KW FOR 200% 3S,150% 57S,100% 240S AMBIENT TEMP. -10 TO +50 DEG C OUTPUT LOW OVERLOAD: 1,5KW AT 150% 3S,110% 57S,100% 240S AMBIENT TEMP. -10 TO +40 DEG C 196 X 73 X 165 (HXWXD), FSA PROTECTION IP20 WITHOUT CONTROL UNIT AND PANEL APPROVED FOR FIRMWARE-VERSION V4.6
In partner stock - ships in 3-5 days
In partner stock - ships in 3-5 days
SINAMICS POWER MODULE PM240-2 UNFILTERED WITH BUILT IN BRAKING CHOPPER 3AC380-480V +10/-10% 47-63HZ OUTPUT HIGH OVERLOAD: 2,2KW FOR 200% 3S,150% 57S,100% 240S AMBIENT TEMP. -10 TO +50 DEG C OUTPUT LOW OVERLOAD: 3KW AT 150% 3S,110% 57S,100% 240S AMBIENT TEMP. -10 TO +40 DEG C 196 X 73 X 165 (HXWXD), FSA PROTECTION IP20 WITHOUT CONTROL UNIT AND PANEL APPROVED FOR CU FIRMWARE-VERSION V4.6
SINAMICS POWER MODULE PM240-2 UNFILTERED WITH BUILT IN BRAKING CHOPPER 3AC380-480V +10/-10% 47-63HZ OUTPUT HIGH OVERLOAD: 2,2KW FOR 200% 3S,150% 57S,100% 240S AMBIENT TEMP. -10 TO +50 DEG C OUTPUT LOW OVERLOAD: 3KW AT 150% 3S,110% 57S,100% 240S AMBIENT TEMP. -10 TO +40 DEG C 196 X 73 X 165 (HXWXD), FSA PROTECTION IP20 WITHOUT CONTROL UNIT AND PANEL APPROVED FOR CU FIRMWARE-VERSION V4.6
In partner stock - ships in 3-5 days

In partner stock - ships in 3-5 days
SINAMICS POWER MODULE PM240-2 WITH BUILT IN CL. A FILTER WITH BUILT IN BRAKING CHOPPER 3AC380-480V +10/-10% 47-63HZ OUTPUT HIGH OVERLOAD: 7,5KW FOR 200% 3S,150% 57S,100% 240S AMBIENT TEMP -10 TO +50 DEG C OUTPUT LOW OVERLOAD: 11KW FOR 150% 3S,110% 57S,100

SINAMICS POWER MODULE PM240-2 WITH BUILT IN CL. A FILTER WITH BUILT IN BRAKING CHOPPER 3AC380-480V +10/-10% 47-63HZ OUTPUT HIGH OVERLOAD: 7,5KW FOR 200% 3S,150% 57S,100% 240S AMBIENT TEMP -10 TO +50 DEG C OUTPUT LOW OVERLOAD: 11KW FOR 150% 3S,110% 57S,100
In partner stock - ships in 3-5 days

In partner stock - ships in 3-5 days
SINAMICS POWER MODULE PM240-2 WITH BUILT IN CL. A FILTER WITH BUILT IN BRAKING CHOPPER 3AC380-480V +10/-10% 47-63HZ OUTPUT HIGH OVERLOAD: 11KW FOR 200% 3S,150% 57S,100% 240S AMBIENT TEMP -10 TO +50 DEG C OUTPUT LOW OVERLOAD: 15KW FOR 150% 3S,110% 57S,100% 240S AMBIENT TEMP -10 TO +40 DEG C 355 X 140 X 165 (HXWXD), FSC PROTECTION IP20 WITHOUT CONTROL UNIT AND PANEL APPROVED FOR CU FIRMWARE- VERSION V4.6

SINAMICS POWER MODULE PM240-2 WITH BUILT IN CL. A FILTER WITH BUILT IN BRAKING CHOPPER 3AC380-480V +10/-10% 47-63HZ OUTPUT HIGH OVERLOAD: 11KW FOR 200% 3S,150% 57S,100% 240S AMBIENT TEMP -10 TO +50 DEG C OUTPUT LOW OVERLOAD: 15KW FOR 150% 3S,110% 57S,100% 240S AMBIENT TEMP -10 TO +40 DEG C 355 X 140 X 165 (HXWXD), FSC PROTECTION IP20 WITHOUT CONTROL UNIT AND PANEL APPROVED FOR CU FIRMWARE- VERSION V4.6
In partner stock - ships in 3-5 days

In partner stock - ships in 3-5 days
SINAMICS G120 POWER MODULE PM240-2 WITH BUILT IN CL. A FILTER WITH BUILT IN BRAKING CHOPPER 3AC380-480V +10/-20% 47-63HZ OUTPUT HIGH OVERLOAD: 18.5KW FOR 200% 3S,150% 57S,100% 240S AMBIENT TEMP -20 TO +50 DEG C (HO) OUTPUT LOW OVERLOAD: 22KW FOR 150% 3S,1

SINAMICS G120 POWER MODULE PM240-2 WITH BUILT IN CL. A FILTER WITH BUILT IN BRAKING CHOPPER 3AC380-480V +10/-20% 47-63HZ OUTPUT HIGH OVERLOAD: 18.5KW FOR 200% 3S,150% 57S,100% 240S AMBIENT TEMP -20 TO +50 DEG C (HO) OUTPUT LOW OVERLOAD: 22KW FOR 150% 3S,1
In partner stock - ships in 3-5 days
In partner stock - ships in 3-5 days
SINAMICS S120 CONVERTER POWER MODULE PM340 INPUT: 3AC 380-480V, 50/60HZ OUTPUT: 3AC 5,9A (2,2KW) FRAME SIZE: BLOCKSIZE SIZE FSB WITH INTEGRATED LINE FILTER INTERNAL AIR COOLING
SINAMICS S120 CONVERTER POWER MODULE PM340 INPUT: 3AC 380-480V, 50/60HZ OUTPUT: 3AC 5,9A (2,2KW) FRAME SIZE: BLOCKSIZE SIZE FSB WITH INTEGRATED LINE FILTER INTERNAL AIR COOLING
In partner stock - ships in 3-5 days

In partner stock - ships in 3-5 days
SINAMICS V20 200-240V1AC-10/+10% 47-63HZ RATED POWER 0.25 KW WITH 150% OVERLOAD FOR 60 SEC. INTEGRATED FILTER C1 I/O INTERFACE: 4 DI, 2 DO, 2 AI, 1 AO FIELDBUS: USS/MODBUS RTU WITH BUILT-IN BOP DEGREE OF PROTECTION IP20/UL OP VARIABLE: FSAA 68X142X108

SINAMICS V20 200-240V1AC-10/+10% 47-63HZ RATED POWER 0.25 KW WITH 150% OVERLOAD FOR 60 SEC. INTEGRATED FILTER C1 I/O INTERFACE: 4 DI, 2 DO, 2 AI, 1 AO FIELDBUS: USS/MODBUS RTU WITH BUILT-IN BOP DEGREE OF PROTECTION IP20/UL OP VARIABLE: FSAA 68X142X108
In partner stock - ships in 3-5 days
In partner stock - ships in 3-5 days
SINAMICS V20 200-240V1AC-10/+10% 47-63HZ RATED POWER 0.75 KW/1 HP WITH 150% OVERLOAD FOR 60 SEC. INTEGRATED FILTER C1 I/O INTERFACE: 4 DI, 2 DO, 2 AI, 1 AO FIELDBUS: USS/MODBUS RTU WITH BUILT-IN BOP DEGREE OF PROTECTION IP20/UL OP VARIABLE: FSAB 68X142X12
SINAMICS V20 200-240V1AC-10/+10% 47-63HZ RATED POWER 0.75 KW/1 HP WITH 150% OVERLOAD FOR 60 SEC. INTEGRATED FILTER C1 I/O INTERFACE: 4 DI, 2 DO, 2 AI, 1 AO FIELDBUS: USS/MODBUS RTU WITH BUILT-IN BOP DEGREE OF PROTECTION IP20/UL OP VARIABLE: FSAB 68X142X12
In partner stock - ships in 3-5 days