Carrello
Nessun prodotto nel carrello
Continuare lo shoppingNessun prodotto nel carrello
Continuare lo shoppingIn magazzino partner - spedizione in 3-5 giorni
SINAMICS G110 - CPM110 AC-DRIVE, WITHOUT FILTER 1AC200-240V +10/-10% 47-63HZ ANALOG INPUT CT: 1,1KW; VT: 1,1KW CT-OVERLOAD: 150% 60S 160 X 140 X 142 (HXWXD) PROTECTION IP20 AMBIENT TEMP -10 TO +50 DEG C WITHOUT BOP WITHOUT RS485-INTERFACE
SINAMICS G110 - CPM110 AC-DRIVE, WITHOUT FILTER 1AC200-240V +10/-10% 47-63HZ ANALOG INPUT CT: 1,1KW; VT: 1,1KW CT-OVERLOAD: 150% 60S 160 X 140 X 142 (HXWXD) PROTECTION IP20 AMBIENT TEMP -10 TO +50 DEG C WITHOUT BOP WITHOUT RS485-INTERFACE
In magazzino partner - spedizione in 3-5 giorni
In magazzino partner - spedizione in 3-5 giorni
SINAMICS G110 - CPM110 AC-DRIVE,BUILT IN CL. A FILTER 1AC200-240V +10/-10% 47-63HZ ANALOG INPUT CT: 1,5KW; VT: 1,5KW CT-OVERLOAD: 150% 60S 160 X 140 X 142 (HXWXD) PROTECTION IP20 AMBIENT TEMP -10 TO +40 DEG C WITHOUT BOP WITHOUT RS485-INTERFACE
SINAMICS G110 - CPM110 AC-DRIVE,BUILT IN CL. A FILTER 1AC200-240V +10/-10% 47-63HZ ANALOG INPUT CT: 1,5KW; VT: 1,5KW CT-OVERLOAD: 150% 60S 160 X 140 X 142 (HXWXD) PROTECTION IP20 AMBIENT TEMP -10 TO +40 DEG C WITHOUT BOP WITHOUT RS485-INTERFACE
In magazzino partner - spedizione in 3-5 giorni
In magazzino partner - spedizione in 3-5 giorni
SINAMICS G110 200-240V 1,5KW USS
SINAMICS G110 200-240V 1,5KW USS
In magazzino partner - spedizione in 3-5 giorni
In magazzino partner - spedizione in 3-5 giorni
SINAMICS G110 - CPM110 AC-DRIVE, MIT INTEGR. FILTER A 1AC200-240V +10/-10% 47-63HZ ANALOGEINGANG CT: 2,2KW; VT: 2,2KW CT-UEBERLAST: 150% 60S 181 X 184 X 152 (HXBXT) SCHUTZART IP20 UMGEBUNGSTEMPERATUR -10+50GRD C OHNE BOP OHNE RS485-INTERFACE
SINAMICS G110 - CPM110 AC-DRIVE, MIT INTEGR. FILTER A 1AC200-240V +10/-10% 47-63HZ ANALOGEINGANG CT: 2,2KW; VT: 2,2KW CT-UEBERLAST: 150% 60S 181 X 184 X 152 (HXBXT) SCHUTZART IP20 UMGEBUNGSTEMPERATUR -10+50GRD C OHNE BOP OHNE RS485-INTERFACE
In magazzino partner - spedizione in 3-5 giorni
In magazzino partner - spedizione in 3-5 giorni
SINAMICS G110 - CPM110 AC-DRIVE, MIT INTEGR. FILTER A 1AC200-240V +10/-10% 47-63HZ RS485-INTERFACE (USS-PROTOKOLL) CT: 2,2KW; VT: 2,2KW CT-UEBERLAST: 150% 60S 181 X 184 X 152 (HXBXT) SCHUTZART IP20 UMGEBUNGSTEMPERATUR -10+50GRD C OHNE BOP OHNE ANALOGEINGANG
SINAMICS G110 - CPM110 AC-DRIVE, MIT INTEGR. FILTER A 1AC200-240V +10/-10% 47-63HZ RS485-INTERFACE (USS-PROTOKOLL) CT: 2,2KW; VT: 2,2KW CT-UEBERLAST: 150% 60S 181 X 184 X 152 (HXBXT) SCHUTZART IP20 UMGEBUNGSTEMPERATUR -10+50GRD C OHNE BOP OHNE ANALOGEINGANG
In magazzino partner - spedizione in 3-5 giorni
In magazzino partner - spedizione in 3-5 giorni
SINAMICS G110 - CPM110 AC-DRIVE, UNGEFILTERT 1AC200-240V +10/-10% 47-63HZ ANALOGEINGANG CT: 2,2KW; VT: 2,2KW CT-UEBERLAST: 150% 60S 181 X 184 X 152 (HXBXT) SCHUTZART IP20 UMGEBUNGSTEMPERATUR -10+50GRD C OHNE BOP OHNE RS485-INTERFACE
SINAMICS G110 - CPM110 AC-DRIVE, UNGEFILTERT 1AC200-240V +10/-10% 47-63HZ ANALOGEINGANG CT: 2,2KW; VT: 2,2KW CT-UEBERLAST: 150% 60S 181 X 184 X 152 (HXBXT) SCHUTZART IP20 UMGEBUNGSTEMPERATUR -10+50GRD C OHNE BOP OHNE RS485-INTERFACE
In magazzino partner - spedizione in 3-5 giorni
In magazzino partner - spedizione in 3-5 giorni
SINAMICS G110 200-240V 0,12KWAIN/DINFLAT
SINAMICS G110 200-240V 0,12KWAIN/DINFLAT
In magazzino partner - spedizione in 3-5 giorni
In magazzino partner - spedizione in 3-5 giorni
SINAMICS G110 200-240V 0,12KW USS FLAT
SINAMICS G110 200-240V 0,12KW USS FLAT
In magazzino partner - spedizione in 3-5 giorni
In magazzino partner - spedizione in 3-5 giorni
SINAMICS G110 - CPM110 AC-DRIVE, MIT INTEGR. FILTER B 1AC200-240V +10/-10% 47-63HZ RS485-INTERFACE (USS-PROTOKOLL) CT: 0,37KW; VT: 0,37KW CT-UEBERLAST: 150% 60S 150 X 90 X 101 (HXBXT) IP20; MIT FLACHEM KUEHLKOERPER; NUR FUER KUEHLPLATTENMONTAGE UMGEBUNGSTEMPERATUR -10+50GRD C OHNE BOP OHNE ANALOGEINGANG
SINAMICS G110 - CPM110 AC-DRIVE, MIT INTEGR. FILTER B 1AC200-240V +10/-10% 47-63HZ RS485-INTERFACE (USS-PROTOKOLL) CT: 0,37KW; VT: 0,37KW CT-UEBERLAST: 150% 60S 150 X 90 X 101 (HXBXT) IP20; MIT FLACHEM KUEHLKOERPER; NUR FUER KUEHLPLATTENMONTAGE UMGEBUNGSTEMPERATUR -10+50GRD C OHNE BOP OHNE ANALOGEINGANG
In magazzino partner - spedizione in 3-5 giorni
In magazzino partner - spedizione in 3-5 giorni
SINAMICS G110 - CPM110 AC-DRIVE, UNGEFILTERT 1AC200-240V +10/-10% 47-63HZ RS485-INTERFACE (USS-PROTOKOLL) CT: 0,55KW; VT: 0,55KW CT-UEBERLAST: 150% 60S 150 X 90 X 101 (HXBXT) IP20; MIT FLACHEM KUEHLKOERPER; NUR FUER KUEHLPLATTENMONTAGE UMGEBUNGSTEMPERATUR -10+50GRD C OHNE BOP OHNE ANALOGEINGANG
SINAMICS G110 - CPM110 AC-DRIVE, UNGEFILTERT 1AC200-240V +10/-10% 47-63HZ RS485-INTERFACE (USS-PROTOKOLL) CT: 0,55KW; VT: 0,55KW CT-UEBERLAST: 150% 60S 150 X 90 X 101 (HXBXT) IP20; MIT FLACHEM KUEHLKOERPER; NUR FUER KUEHLPLATTENMONTAGE UMGEBUNGSTEMPERATUR -10+50GRD C OHNE BOP OHNE ANALOGEINGANG
In magazzino partner - spedizione in 3-5 giorni
In magazzino partner - spedizione in 3-5 giorni
In magazzino partner - spedizione in 3-5 giorni
In magazzino partner - spedizione in 3-5 giorni
In magazzino partner - spedizione in 3-5 giorni
In magazzino partner - spedizione in 3-5 giorni
In magazzino partner - spedizione in 3-5 giorni
In magazzino partner - spedizione in 3-5 giorni
In magazzino partner - spedizione in 3-5 giorni
In magazzino partner - spedizione in 3-5 giorni
In magazzino partner - spedizione in 3-5 giorni
In magazzino partner - spedizione in 3-5 giorni
In magazzino partner - spedizione in 3-5 giorni
In magazzino partner - spedizione in 3-5 giorni
In magazzino partner - spedizione in 3-5 giorni
In magazzino partner - spedizione in 3-5 giorni
In magazzino partner - spedizione in 3-5 giorni
In magazzino partner - spedizione in 3-5 giorni
In magazzino partner - spedizione in 3-5 giorni
In magazzino partner - spedizione in 3-5 giorni
In magazzino partner - spedizione in 3-5 giorni