Carrello
Nessun prodotto nel carrello
Continuare lo shoppingNessun prodotto nel carrello
Continuare lo shopping
In magazzino partner - spedizione in 3-5 giorni
SINAMICS G110 - CPM110 AC-DRIVE,BUILT IN CL. B FILTER 1AC200-240V +10/-10% 47-63HZ ANALOG INPUT CT: 0,55KW; VT: 0,55KW CT-OVERLOAD: 150% 60S 150 X 90 X 131 (HXWXD) PROTECTION IP20 AMBIENT TEMP -10 TO +50 DEG C WITHOUT BOP WITHOUT RS485-INTERFAC

SINAMICS G110 - CPM110 AC-DRIVE,BUILT IN CL. B FILTER 1AC200-240V +10/-10% 47-63HZ ANALOG INPUT CT: 0,55KW; VT: 0,55KW CT-OVERLOAD: 150% 60S 150 X 90 X 131 (HXWXD) PROTECTION IP20 AMBIENT TEMP -10 TO +50 DEG C WITHOUT BOP WITHOUT RS485-INTERFAC
In magazzino partner - spedizione in 3-5 giorni

In magazzino partner - spedizione in 3-5 giorni
SINAMICS G110 - CPM110 AC-DRIVE,BUILT IN CL. A FILTER 1AC200-240V +10/-10% 47-63HZ ANALOG INPUT CT: 1,1KW; VT: 1,1KW CT-OVERLOAD: 150% 60S 160 X 140 X 142 (HXWXD) PROTECTION IP20 AMBIENT TEMP -10 TO +50 DEG C WITHOUT BOP WITHOUT RS485-INTERFACE

SINAMICS G110 - CPM110 AC-DRIVE,BUILT IN CL. A FILTER 1AC200-240V +10/-10% 47-63HZ ANALOG INPUT CT: 1,1KW; VT: 1,1KW CT-OVERLOAD: 150% 60S 160 X 140 X 142 (HXWXD) PROTECTION IP20 AMBIENT TEMP -10 TO +50 DEG C WITHOUT BOP WITHOUT RS485-INTERFACE
In magazzino partner - spedizione in 3-5 giorni
In magazzino partner - spedizione in 3-5 giorni
SINAMICS G120 POWER MODULE PM250 WITH BUILT IN CL. A FILTER POSSIBILITY OF REGENERATION 3AC380-480V +10/-10% 47-63HZ OUTPUT HIGH OVERLOAD: 30KW FOR 200% 3S,150% 57S,100% 240S AMBIENT TEMP -10 TO +50 DEG C OUTPUT LIGHT OVERLOAD: 37KW FOR 150% 3S,110% 57S,100% 240S AMBIENT TEMP -10 TO +40 DEG C 635 X 275 X 204 (HXWXD), FSE PROTECTION IP20 WITHOUT CONTROL UNIT AND BOP
SINAMICS G120 POWER MODULE PM250 WITH BUILT IN CL. A FILTER POSSIBILITY OF REGENERATION 3AC380-480V +10/-10% 47-63HZ OUTPUT HIGH OVERLOAD: 30KW FOR 200% 3S,150% 57S,100% 240S AMBIENT TEMP -10 TO +50 DEG C OUTPUT LIGHT OVERLOAD: 37KW FOR 150% 3S,110% 57S,100% 240S AMBIENT TEMP -10 TO +40 DEG C 635 X 275 X 204 (HXWXD), FSE PROTECTION IP20 WITHOUT CONTROL UNIT AND BOP
In magazzino partner - spedizione in 3-5 giorni

In magazzino partner - spedizione in 3-5 giorni
SINAMICS G120P BT UNITÀ DI CONTROLLO CU230P-2 BT USS/ MODBUS RTU/BACNET MS/TP 6 DI, 3 DO, 4 AI, 2 AO 1 INGRESSO SENSORE TEMP. MOT. INGRESSO SENSORE TEMPERATURA MOTORE 2 USCITE PSU (10V DC, 24V DC) 1 INGRESSO PSU (24V DC) INTERFACCIA USB E MMC PROTEZIONE IP20

SINAMICS G120P BT UNITÀ DI CONTROLLO CU230P-2 BT USS/ MODBUS RTU/BACNET MS/TP 6 DI, 3 DO, 4 AI, 2 AO 1 INGRESSO SENSORE TEMP. MOT. INGRESSO SENSORE TEMPERATURA MOTORE 2 USCITE PSU (10V DC, 24V DC) 1 INGRESSO PSU (24V DC) INTERFACCIA USB E MMC PROTEZIONE IP20
In magazzino partner - spedizione in 3-5 giorni

In magazzino partner - spedizione in 3-5 giorni
SINAMICS G120 UNITÀ DI CONTROLLO CU240E-2 DP-F E-TYPE SICUREZZA INTEGRATA STO, SS1, SLS, PROFIBUS DP 6DI, 3DO, 2AI, 2AO, MAX 3F-DI INTERFACCIA PTC / KTY INTERFACCIA USB E SD / MMC PROTEZIONE IP20 SISTEMA AMBIENTALE , DA 0 A +50 GRD C SENZA MODULI DI POTENZA

SINAMICS G120 UNITÀ DI CONTROLLO CU240E-2 DP-F E-TYPE SICUREZZA INTEGRATA STO, SS1, SLS, PROFIBUS DP 6DI, 3DO, 2AI, 2AO, MAX 3F-DI INTERFACCIA PTC / KTY INTERFACCIA USB E SD / MMC PROTEZIONE IP20 SISTEMA AMBIENTALE , DA 0 A +50 GRD C SENZA MODULI DI POTENZA
In magazzino partner - spedizione in 3-5 giorni
In magazzino partner - spedizione in 3-5 giorni
FREQUENCY CONVERTER FOR ET 200S CONTROL UNIT MODULE WIDTH 15 MM COMBINEABLE WITH CONVERTER POWER MODULE IPM25 CONTROL METHODS: U/F,FCC,SLVC, VC WITH ENCODER, TORQUE CONTROL INPUT MOTOR ENC.: HTL UNIPOLAR INPUT MOTOR TEMP.: PTC/KTY RS232: START-UP-TOOL STARTER
FREQUENCY CONVERTER FOR ET 200S CONTROL UNIT MODULE WIDTH 15 MM COMBINEABLE WITH CONVERTER POWER MODULE IPM25 CONTROL METHODS: U/F,FCC,SLVC, VC WITH ENCODER, TORQUE CONTROL INPUT MOTOR ENC.: HTL UNIPOLAR INPUT MOTOR TEMP.: PTC/KTY RS232: START-UP-TOOL STARTER
In magazzino partner - spedizione in 3-5 giorni

In magazzino partner - spedizione in 3-5 giorni
SINAMICS G120 PANNELLO OPERATORE INTELLIGENTE (IOP)

SINAMICS G120 PANNELLO OPERATORE INTELLIGENTE (IOP)
In magazzino partner - spedizione in 3-5 giorni

In magazzino partner - spedizione in 3-5 giorni
SINAMICS G120 PANNELLO OPERATORE INTELLIGENTE IOP PANNELLO DI CONTROLLO OPZIONALE PER SINAMICS G120, G120P G110M, G110D, G120D, G120C S110, ET 200S FC, ET 200 PRO FC LINGUE SUPPORTATE: CINESE, INGLESE, TEDESCO

SINAMICS G120 PANNELLO OPERATORE INTELLIGENTE IOP PANNELLO DI CONTROLLO OPZIONALE PER SINAMICS G120, G120P G110M, G110D, G120D, G120C S110, ET 200S FC, ET 200 PRO FC LINGUE SUPPORTATE: CINESE, INGLESE, TEDESCO
In magazzino partner - spedizione in 3-5 giorni

In magazzino partner - spedizione in 3-5 giorni
SINAMICS G120D CONTROL UNIT CU240D DP PROFIBUS UND SAFETY INTEGRATED 6 DI, 2 DO PTC/KTY INTERFACE EM-BRAKE CONTROL, MMC INTERFACE ENCODER INTERFACE PROTECTION IP65 AMBIENT TEMP -10 TO +55 DEG C WITHOUT POWER MODULE

SINAMICS G120D CONTROL UNIT CU240D DP PROFIBUS UND SAFETY INTEGRATED 6 DI, 2 DO PTC/KTY INTERFACE EM-BRAKE CONTROL, MMC INTERFACE ENCODER INTERFACE PROTECTION IP65 AMBIENT TEMP -10 TO +55 DEG C WITHOUT POWER MODULE
In magazzino partner - spedizione in 3-5 giorni
In magazzino partner - spedizione in 3-5 giorni
SIMODRIVE 611 FILTRO DI RETE PER MODULI NON REGOLATI 5 KW FINO A 480 V DI ALIMENTAZIONE DI RETE
SIMODRIVE 611 FILTRO DI RETE PER MODULI NON REGOLATI 5 KW FINO A 480 V DI ALIMENTAZIONE DI RETE
In magazzino partner - spedizione in 3-5 giorni
In magazzino partner - spedizione in 3-5 giorni
SIMODRIVE 611 OPZIONE UNIVERSALE PLUG-IN PROFIBUS DP, PROFIBUS PLUG-IN DP-NORM-SLAVE PER SCAMBIO DATI CICLICO E ACICLICO
SIMODRIVE 611 OPZIONE UNIVERSALE PLUG-IN PROFIBUS DP, PROFIBUS PLUG-IN DP-NORM-SLAVE PER SCAMBIO DATI CICLICO E ACICLICO
In magazzino partner - spedizione in 3-5 giorni

In magazzino partner - spedizione in 3-5 giorni
SIMODRIVE 611 DIGITALE HIGH PERFORMANCE 2 ASSI SEN/COS 1 VPP. NC SOFTWARE NECESSARIO DALLA VERSIONE 06.04.09

SIMODRIVE 611 DIGITALE HIGH PERFORMANCE 2 ASSI SEN/COS 1 VPP. NC SOFTWARE NECESSARIO DALLA VERSIONE 06.04.09
In magazzino partner - spedizione in 3-5 giorni

In magazzino partner - spedizione in 3-5 giorni
SIMODRIVE POSMO A MOTORE POSIZIONATORE PROGRAMMABILE PROFIBUS-DP NORM-SLAVE MOTORE SENZA SPAZZOLE 48V 300W RIDUTTORE A PIANETI I=4 SENZA FRENO IP54

SIMODRIVE POSMO A MOTORE POSIZIONATORE PROGRAMMABILE PROFIBUS-DP NORM-SLAVE MOTORE SENZA SPAZZOLE 48V 300W RIDUTTORE A PIANETI I=4 SENZA FRENO IP54
In magazzino partner - spedizione in 3-5 giorni